Available in various lengths, the cable assemblies can be used as either drop cable* from an NMEA 2000 backbone or to extend the length of the backbone cable.
Actisense Lite cable assemblies allow quick installation and come with a quality reassurance, as only the Actisense UL certified cable is used.
NMEA 2000 cable includes five wires within a single waterproof cable: power and ground wires, two signal (data) wires and a drain wire. The drain wire connects to the cable shield which protects the signal, power and ground wires from external Radio Frequency Interference (RFI) and helps reduce RFI emission from the cable.
NMEA 2000 Lite cable can be used to create a backbone up to 100 metres in length. If the backbone length required exceeds 100 metres, the centre of the bus can be extended with NMEA 2000 mini cable to keep the outer Lite sections to the 100-metre maximum.
NMEA 2000 cable includes five wires within a single waterproof cable: power and ground wires, two signal (data) wires and a drain wire. The drain wire connects to the cable shield which protects the signal, power and ground wires from external Radio Frequency Interference (RFI) and helps reduce RFI emission from the cable.
NMEA 2000 Lite cable can be used to create a backbone up to 100 metres in length. If the backbone length required exceeds 100 metres, the centre of the bus can be extended with NMEA 2000 mini cable to keep the outer Lite sections to the 100-metre maximum.
The maximum permitted length of a drop cable (distance from the backbone) is 6 metres. It is important to limit each drop length to the minimum required as the total of all drop lengths must not exceed 72 metres.
Technical Specification
Electrical | |
Rated Current | 4A |
Rated Voltage | 60VDC |
Mechanical | |
Male Contact | Brass, gold plated |
Female Contact | Phosphor bronze, gold plated |
Contact Carrier | PBT, black |
Contact Polarisation | Standard M12 -“A”- polarisation |
Mating Thread | M12 |
Screw Cap | Brass, nickel plated |
O-Ring Seal | Rubber, black |
Housing | PVC, black |
Power Pair | 22 AWG (19 strand tinned copper) |
Data Pair | 24 AWG (19 strand tinned copper) |
Drain | 22 AWG (19 strand tinned copper) |
Braid | 37 AWG (tinned copper) |
Jacket Material | 0.8mm Nom. PVC, black |
Jacket Outer Diameter | 6.85mm ±0.254mm |
Weights | 0.25m: 51g, 0.5m: 67g, |
1m: 102g, 2m: 166g, | |
5m: 379g, 6m : 447g, | |
8m: 570g, 10m: 733g | |
Approvals and Certifications | |
Protection | IP67 (when mated) |
Operating Temperature | -20°C to +70°C |
Storage Temperature | -40°C to +85°C |
NMEA 2000 Approved | |
RoHS Compliant | |
UL Certified (E137250), (UL1277) |